Description / Abstract:
These requirements apply to membrane switches actuated by human
activity, via a membrane or sensing substrate, to operate or
control appliances and electrical equipment. The membrane switch
electrical rating not to exceed 30 Vrms and power not greater than
100 VA.
When this outline references "switches" it shall mean "membrane
switches" unless specifically indicated.
Membrane switches which incorporate additional control functions
governed by the switch function are within the scope of these
requirements. Additional control functions shall be evaluated for
their suitability using the applicable standards for the
application.
These membrane switches are intended to be operated by a person,
via a membrane or by actuating a sensing substrate.
These requirements cover the indirect actuation of the switch
when the operation of the actuating member or sensing unit is
provided by a remote control or a part of an appliance or equipment
such as a door.
Embedded components are evaluated with regards to their safety
and application to the membrane switch construction. The
acceptability of an embedded component in the membrane switch shall
be considered with regards to construction and performance
requirements in the end product final application.