More info
Description / Abstract:
This Practice describes the general requirements for the design,
materials, fabrication, examination, inspection, testing,
certification (ASME stamp and Supplier's Data Report), and pressure
relief of aboveground fiberglass reinforced polyester, vinyl ester,
and epoxy tanks and vessels having internal or external pressure
from full vacuum up to the limits of Code Section X. This
Practice covers shop- and fieldfabricated equipment,
thermoplastic-lined equipment, and dual laminate equipment.
This Practice does not cover the following equipment items that
are excluded from both ASME/ANSI RTP-1 and Code
Section X:
a. Portable or movable containers
b. Hoods, ducts, and stacks
c. Fans and blowers
d. Vessel internals such as entrainment separators, chevron
blades, packing support plates, and liquid distributor plates
e. Pipe or piping
f. Fully buried underground closed vessels
This Practice does not cover the following equipment items that
are excluded from Code Section X:
a. Vessels having an inside diameter (ID), width, height, or
cross-section diagonal of 6 inches (150 mm) or less, with no
limitation on length or pressure. The 6-inch (150 mm) dimension
excludes (150 mm) the thickness of any corrosion liner.
b.Vessels containing lethal substances as designated by the
owner in accordance with Code Section X Paragraph
RG-113.
This Practice does not cover the following equipment items that
are excluded from ASME/ANSI RTP-1:
a. Vessels constructed of furan, epoxy, or phenolic resins
b. Vessels with non-glass structural reinforcements
c. Vessels having metallic liners
Purpose
This Practice provides requirements for the construction of
fiberglass vessels and tanks in accordance with ASME Boiler and
Pressure Vessel Code Section X "Fiber- Reinforced Plastic
Pressure Vessels" or ASME/ANSI RTP-1 "Reinforced Thermoset
Plastic (RTP) Corrosion Resistant Equipment."